Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 626
1.
J Infect Dev Ctries ; 18(4): 595-599, 2024 Apr 30.
Article En | MEDLINE | ID: mdl-38728642

INTRODUCTION: This study aims to show the bacteriologic picture of acute prostatitis and bacteremia caused by infective agent after transrectal ultrasound-guided prostate biopsy (TRUSBx) and to determine the resistance rates of the infections in patients undergoing transrectal biopsy and to guide prophylaxis approach before biopsy. METHODOLOGY: The retrospective data of 935 patients who underwent TRUSBx between January 2010 to January 2019 were reviewed. Pre-biopsy urine cultures and antimicrobial susceptibility were obtained. Subsequently, patients admitted to the hospital with any complaint after biopsy were examined for severe infection complications. RESULTS: Of the 430 (61.7%) patients who underwent urine culture before the procedure, 45 (10.5%) had growth; 30 (66.7%) of the growing microorganisms were Escherichia coli. Twenty (44.4%) of all Gram-negative agents in pre-biopsy urine culture were susceptible to quinolone. Post TRUSBx bacteremia was present in 18.2%, urinary system infection in 83.6%, and hospitalization in 61.8% of 55 patients who were admitted to the hospital. In the isolated gram-negative microorganisms, fluoroquinolones resistance in urinary system infections was seen in 40% and bacteremia was seen in 70% of the cases. ESBL-producing Gram-negative bacteria were determined in 40% of infections in blood and 38.5% of urinary system infections in the post biopsy period in the current study. CONCLUSIONS: These high antibiotic resistance rates suggest that we better review our pre-procedure prophylaxis approaches.


Anti-Bacterial Agents , Antibiotic Prophylaxis , Bacteremia , Prostate , Humans , Male , Retrospective Studies , Antibiotic Prophylaxis/methods , Middle Aged , Aged , Prostate/pathology , Prostate/microbiology , Anti-Bacterial Agents/therapeutic use , Anti-Bacterial Agents/pharmacology , Bacteremia/prevention & control , Bacteremia/microbiology , Drug Resistance, Bacterial , Prostatitis/microbiology , Prostatitis/prevention & control , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Urinary Tract Infections/prevention & control , Urinary Tract Infections/microbiology
2.
Folia Med (Plovdiv) ; 66(2): 179-187, 2024 Apr 30.
Article En | MEDLINE | ID: mdl-38690812

INTRODUCTION: Evaluation of patients with peripheral lung lesions and lesions of the chest wall and mediastinum is challenging. The nature of the lesion identified by imaging studies can be determined by histological evaluation of biopsies. An important place in this direction is the ever-increasing popularity among thoracic surgeons of the transthoracic biopsy with a cutting needle under ultrasound control (US-TTCNB).


Mediastinum , Thoracic Wall , Humans , Thoracic Wall/diagnostic imaging , Thoracic Wall/pathology , Mediastinum/pathology , Mediastinum/diagnostic imaging , Lung Neoplasms/pathology , Lung Neoplasms/diagnostic imaging , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Lung Diseases/pathology , Lung Diseases/diagnostic imaging , Lung Diseases/etiology , Lung/pathology , Lung/diagnostic imaging , Biopsy, Needle/adverse effects , Biopsy, Needle/methods
3.
Cardiovasc Intervent Radiol ; 47(5): 621-631, 2024 May.
Article En | MEDLINE | ID: mdl-38639781

PURPOSE: CT-guided percutaneous core biopsy of the lung is usually performed under local anesthesia, but can also be conducted under additional systemic opioid medication. The purpose of this retrospective study was to assess the effect of intravenous piritramide application on the pneumothorax rate and to identify risk factors for post-biopsy pneumothorax. MATERIALS AND METHODS: One hundred and seventy-one core biopsies of the lung were included in this retrospective single center study. The incidence of pneumothorax and chest tube placement was evaluated. Patient-, procedure- and target-related variables were analyzed by univariate and multivariable logistic regression analysis. RESULTS: The overall incidence of pneumothorax was 39.2% (67/171). The pneumothorax rate was 31.5% (29/92) in patients who received intravenous piritramide and 48.1% (38/79) in patients who did not receive piritramide. In multivariable logistic regression analysis periinterventional piritramide application proved to be the only independent factor to reduce the risk of pneumothorax (odds ratio 0.46, 95%-confidence interval 0.24, 0.88; p = 0.018). Two or more pleura passages (odds ratio 3.38, 95%-confidence interval: 1.15, 9.87; p = 0.026) and prone position of the patient (odds ratio 2.27, 95%-confidence interval: 1.04, 4.94; p = 0.039) were independent risk factors for a higher pneumothorax rate. CONCLUSION: Procedural opioid medication with piritramide proved to be a previously undisclosed factor decreasing the risk of pneumothorax associated with CT-guided percutaneous core biopsy of the lung. LEVEL OF EVIDENCE 4: small study cohort.


Analgesics, Opioid , Image-Guided Biopsy , Lung , Pirinitramide , Pneumothorax , Radiography, Interventional , Tomography, X-Ray Computed , Humans , Pneumothorax/prevention & control , Pneumothorax/etiology , Female , Male , Retrospective Studies , Tomography, X-Ray Computed/methods , Middle Aged , Analgesics, Opioid/administration & dosage , Radiography, Interventional/methods , Aged , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Risk Factors , Lung/diagnostic imaging , Lung/pathology , Pirinitramide/administration & dosage , Pirinitramide/therapeutic use , Adult , Incidence
4.
World J Urol ; 42(1): 252, 2024 Apr 23.
Article En | MEDLINE | ID: mdl-38652324

BACKGROUND: To prevent infectious complications after transrectal ultrasound-guided prostate biopsy (TRUS-PB), some studies have investigated the efficacy of rectal disinfection using povidone-iodine (PI) and antibiotic prophylaxis (AP). OBJECTIVE: To summarize available data and compare the efficacy of rectal disinfection using PI with non-PI methods prior to TRUS-PB. EVIDENCE ACQUISITION: Three databases were queried through November 2023 for randomized controlled trials (RCTs) analyzing patients who underwent TRUS-PB. We compared the effectiveness of rectal disinfection between PI groups and non-PI groups with or without AP. The primary outcomes of interest were the rates of overall infectious complications, fever, and sepsis. Subgroups analyses were conducted to assess the differential outcomes in patients using fluoroquinolone groups compared to those using other antibiotics groups. EVIDENCE SYNTHESIS: We included ten RCTs in the meta-analyses. The overall rates of infectious complications were significantly lower when rectal disinfection with PI was performed (RR 0.56, 95% CI 0.42-0.74, p < 0.001). Compared to AP monotherapy, the combination of AP and PI was associated with significantly lower risk of infectious complications (RR 0.54, 95% CI 0.40-0.73, p < 0.001) and fever (RR 0.47, 95% CI 0.30-0.75, p = 0.001), but not with sepsis (RR 0.49, 95% CI 0.23-1.04, p = 0.06). The use of fluoroquinolone antibiotics was associated with a lower risk of infectious complications and fever compared to non-FQ antibiotics. CONCLUSION: Rectal disinfection with PI significantly reduces the rates of infectious complications and fever in patients undergoing TRUS-PB. However, this approach does not show a significant impact on reducing the rate of sepsis following the procedure.


Anti-Infective Agents, Local , Image-Guided Biopsy , Povidone-Iodine , Prostate , Rectum , Humans , Male , Anti-Infective Agents, Local/therapeutic use , Anti-Infective Agents, Local/administration & dosage , Antibiotic Prophylaxis/methods , Disinfection/methods , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Povidone-Iodine/therapeutic use , Povidone-Iodine/administration & dosage , Prostate/pathology , Prostatic Neoplasms/pathology
5.
Zhonghua Yi Xue Za Zhi ; 104(16): 1403-1409, 2024 Apr 23.
Article Zh | MEDLINE | ID: mdl-38644291

Objective: To investigate the safety and accuracy of CT-guided intracranial puncture biopsy and the possible influencing factors of postoperative bleeding complications. Methods: A case series study. A retrospective analysis was conducted on 101 patients who underwent CT-guided intracranial puncture biopsy at the First Affiliated Hospital of Zhengzhou University from January 2017 to December 2021. The basic data of patients and the safety and accuracy of CT-guided intracranial puncture biopsy were analyzed statistically. Univariate and multivariate logistic regression analysis were used to screen the influencing factors of bleeding complications in CT-guided intracranial puncture biopsy, and the bleeding complications in glioma subgroup were analyzed. Results: Among the 101 patients, 53 were males and 48 were females, aged (53.7±17.2) years. The average diameter of intracranial lesions was (3.5±1.4) cm, while the vertical distance from the lesion to the meninges was (2.4±1.7) cm. The needle's intracranial depth reached (3.2±1.8) cm, with adjustments averaging (3±1) occurrences and an average procedural duration of (40.2±12.9) minutes. Pathological diagnoses included glioma (36 cases), gliosis (3 cases), lymphoma (32 cases), metastatic tumors (7 cases), inflammatory lesions (13 cases), and 10 indeterminate cases. The positive rate of puncture pathology was 90.1% (91/101), and the diagnostic coincidence rate was 94.0% (78/83). The incidence of bleeding complications in CT-guided intracranial puncture biopsy was 26.7% (27/101), of which 23 cases had small intratoma or needle path bleeding, 4 cases had massive bleeding, and 2 cases died. The patients were divided into bleeding group (n=27) and no bleeding group (n=74), according to the presence or absence of bleeding. The results of univariate logistic regression analysis showed that thrombin time≥15 s and the number of needle adjustment were the factors affecting the occurrence of bleeding complications (both P<0.05), and the results of multivariate logistic regression showed that thrombin time≥15 s was the related factor for bleeding. Patients with thrombin time≥15 s had a 3.045 times higher risk of bleeding than those with thrombin time<15 s (OR=3.045,95%CI:1.189-7.799,P=0.020). Among the 101 patients, 36 cases of midbrain glioma were divided into low-grade glioma group (n=11) and high-grade glioma group (n=25) according to the pathological grade. Subgroup analysis showed that the risk of bleeding for high-grade gliomas was 9.231 times higher than that for low-grade gliomas (OR=9.231,95%CI:1.023-83.331,P=0.031). Conclusions: CT-guided intracranial puncture biopsy is safe and feasible with high accuracy. Complication rates are associated with thrombin time≥15 s, especially high-grade glioma, which increases the risk of postoperative bleeding.


Brain Neoplasms , Image-Guided Biopsy , Tomography, X-Ray Computed , Humans , Female , Male , Middle Aged , Retrospective Studies , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Glioma/pathology , Adult , Aged , Brain/pathology , Biopsy, Needle/adverse effects , Biopsy, Needle/methods
6.
Zhongguo Fei Ai Za Zhi ; 27(3): 179-186, 2024 Mar 20.
Article Zh | MEDLINE | ID: mdl-38590192

BACKGROUND: Computed tomography guided percutaneous lung biopsy (CT-PLB) is a widely used method for the diagnosis of lung lesions. However, it is invasive, and the most common complications are pneumothorax and pulmonary hemorrhage, which can be life-threatening in severe cases. Therefore, the aim of this study is to analyze the independent risk factors affecting the occurrence of different complications of CT-PLB, so as to reduce the incidence of complications. METHODS: The 605 patients with complete clinical data who underwent CT-PLB in our hospital from May 2018 to December 2019 were retrospectively analyzed. According to the location of the lesions, they were divided into subpleural group and non-subpleural group. The patients were divided into pneumothorax group, pulmonary hemorrhage group, pneumothorax with pulmonary hemorrhage group and non-pneumothorax/pulmonary hemorrhage group according to the complications. The risk factors affecting the incidence of different complications and the independent risk factors of each complication were analyzed. RESULTS: The incidence of pneumothorax was 34.1%, the incidence of pulmonary hemorrhage was 28.1%, and the incidence of pneumothorax complicated with pulmonary hemorrhage was 10.8% (63 cases). The independent risk factor affecting the incidence of subpleural pneumothorax was lesion size (P=0.002). The independent risk factors affecting the occurrence of pneumothorax in the non-subpleural group were plain scan CT value (P=0.035), length of needle through lung tissue (P=0.003), and thickness of needle through chest wall (P=0.020). Independent risk factors affecting the occurrence of pulmonary hemorrhage in the non-subpleural group were length of needle through lung tissue (P<0.001), △CT value of needle travel area (P=0.001), lesion size (P=0.034) and body position (P=0.014). The independent risk factors affecting the co-occurrence of pneumothorax and pulmonary hemorrhage were the length of needle through lung tissue (P<0.001) and the △CT value of needle travel area (P<0.001). CONCLUSIONS: CT-PLB is a safe and effective diagnostic method, which of high diagnostic value for lung lesions. Selecting the appropriate puncture program can reduce complications such as pneumothorax and pulmonary hemorrhage, and improve diagnosis and treatment efficiency.


Lung Diseases , Lung Neoplasms , Pneumothorax , Thoracic Wall , Humans , Pneumothorax/etiology , Pneumothorax/therapy , Lung Neoplasms/pathology , Retrospective Studies , Lung/diagnostic imaging , Lung/pathology , Lung Diseases/diagnostic imaging , Lung Diseases/etiology , Hemorrhage/etiology , Tomography, X-Ray Computed , Image-Guided Biopsy/adverse effects , Risk Factors
7.
Sci Rep ; 14(1): 7348, 2024 03 28.
Article En | MEDLINE | ID: mdl-38538978

To evaluate the current incidence of pulmonary hemorrhage and the potential factors contributing to its increased risk after percutaneous CT-guided pulmonary nodule biopsy and to summarize the technical recommendations for its treatment. In this observational study, patient data were collected from ten medical centers from April 2021 to April 2022. The incidence of pulmonary hemorrhage was as follows: grade 0, 36.1% (214/593); grade 1, 36.8% (218/593); grade 2, 18.9% (112/593); grade 3, 3.5% (21/593); and grade 4, 4.7% (28/593). High-grade hemorrhage (HGH) occurred in 27.2% (161/593) of the patients. The use of preoperative breathing exercises (PBE, p =0.000), semiautomatic cutting needles (SCN, p = 0.004), immediate contrast enhancement (ICE, p =0.021), and the coaxial technique (CoT, p = 0.000) were found to be protective factors for HGH. A greater length of puncture (p =0.021), the presence of hilar nodules (p = 0.001), the presence of intermediate nodules (p = 0.026), a main pulmonary artery diameter (mPAD) larger than 29 mm (p = 0.015), and a small nodule size (p = 0.014) were risk factors for high-grade hemorrhage. The area under the curve (AUC) was 0.783. These findings contribute to a deeper understanding of the risks associated with percutaneous CT-guided pulmonary nodule biopsy and provide valuable insights for developing strategies to minimize pulmonary hemorrhage.


Cardiovascular Abnormalities , Lung Diseases , Lung Neoplasms , Solitary Pulmonary Nodule , Humans , Incidence , Lung Diseases/diagnostic imaging , Lung Diseases/epidemiology , Lung Diseases/etiology , Hemorrhage/epidemiology , Hemorrhage/etiology , Image-Guided Biopsy/adverse effects , Tomography, X-Ray Computed/methods , Risk Factors , Retrospective Studies , Cardiovascular Abnormalities/etiology , Lung Neoplasms/pathology , Solitary Pulmonary Nodule/diagnostic imaging
11.
J R Coll Physicians Edinb ; 54(1): 14-17, 2024 Mar.
Article En | MEDLINE | ID: mdl-38379306

BACKGROUND: Physician-led thoracic ultrasound (TUS)-guided biopsies provide a prompt route to tissue diagnosis in pleural and peripheral lung malignancies. This retrospective study reviews the diagnostic performance and safety of this approach in a UK District General Hospital. METHODS: Time to biopsy, diagnostic yield and complication rate were analysed in a cohort of 49 patients undergoing ultrasound-guided tissue sampling between September 2019 and December 2022. RESULTS: Fifty-one TUS-guided biopsies were attempted. Mean time from decision to biopsy was 5 days. The overall diagnostic yield was 82%. Complication rate was low; 3 minor adverse effects were reported which led to no change in routine care. CONCLUSION: This single centre retrospective study shows that physician-led TUS-guided biopsy provides a safe and timely method of obtaining a tissue diagnosis in thoracic malignancy. It offers an alternative to computer tomography (CT)-guided or thoracoscopic biopsies and should be considered in selected patients where local procedural expertise exists.


Hospitals, General , Physicians , Humans , Retrospective Studies , Tomography, X-Ray Computed/methods , Image-Guided Biopsy/adverse effects , Biopsy , Ultrasonography, Interventional/adverse effects , Ultrasonography, Interventional/methods
12.
Acta Neurochir (Wien) ; 166(1): 67, 2024 Feb 06.
Article En | MEDLINE | ID: mdl-38319393

PURPOSE: User-friendly robotic assistance and image-guided tools have been developed in the past decades for intraparenchymal brain lesion biopsy. These two methods are gradually becoming well accepted and are performed at the discretion of the neurosurgical teams. However, only a few data comparing their effectiveness and safety are available. METHODS: Population-based parallel cohorts were followed from two French university hospitals with different surgical methods and defined geographical catchment regions (September 2019 to September 2022). In center A, frameless robot-assisted stereotactic intraparenchymal brain lesion biopsies were performed, while image-guided intraparenchymal brain lesion biopsies were performed in center B. Pre-and postoperative clinical, radiological, and histomolecular features were retrospectively collected and compared. RESULTS: Two hundred fifty patients were included: 131 frameless robot-assisted stereotactic intraparenchymal brain lesion biopsies in center A and 119 image-guided biopsies in center B. The clinical, radiological, and histomolecular features were comparable between the two groups. The diagnostic yield (96.2% and 95.8% respectively; p = 1.000) and the overall postoperative complications rates (13% and 14%, respectively; p = 0.880) did not differ between the two groups. The mean duration of the surgical procedure was longer in the robot-assisted group (61.9 ± 25.3 min, range 23-150) than in the image-guided group (47.4 ± 11.8 min, range 25-81, p < 0.001). In the subgroup of patients with anticoagulant and/or antiplatelet therapy administered preoperatively, the intracerebral hemorrhage > 10 mm on postoperative CT scan was higher in the image-guided group (36.8%) than in the robot-assisted group (5%, p < 0.001). CONCLUSION: In our bicentric comparative study, robot-assisted stereotactic and image-guided biopsies have two main differences (shorter time but more frequent postoperative hematoma for image-guided biopsies); however, both techniques are demonstrated to be safe and efficient.


Robotics , Humans , Retrospective Studies , Image-Guided Biopsy/adverse effects , Anticoagulants , Brain
13.
J Med Case Rep ; 18(1): 41, 2024 Feb 03.
Article En | MEDLINE | ID: mdl-38308348

BACKGROUND: The kidney biopsy is a routine procedure. Once an indication has been established, the benefit-risk balance may be considered. Sometimes, even with effective treatment, a severe complication may develop. CASE PRESENTATION: We present the case of a Caucasian 20-year-old young woman admitted to investigating and treating acute kidney injury. Renal involvement was characterized by kidney damage requiring hemodialysis treatment, positive immunologic testing, 0.5 g/day proteinuria, and microscopic hematuria. Contraindications were excluded, so an ultrasound-guided kidney biopsy was performed. To reduce the bleeding complication, Octostim (desmopressin) was administered. There were no direct complications following the kidney biopsy, so we continued the immunosuppressive treatment. Histologically founded thrombotic microangiopathy. However, 1 week later, severe bleeding developed with the need for urgent surgical left kidney removal. CONCLUSION: Kidney biopsy can be considered a routine procedure, and various bleeding episodes are most common in terms of complications, the detection of which is essential. Delayed bleeding complications are rare and can be caused by minor injuries. Our young patient had no injury during the hospitalization. We hypothesized that the developed serious and delayed bleeding complication resulted from effective immunosuppressive treatment. To the best of our knowledge, this is the first such case to date. However, renal biopsy in the case of thrombotic microangiopathy requires caution.


Acute Kidney Injury , Thrombotic Microangiopathies , Female , Humans , Young Adult , Adult , Kidney/pathology , Nephrectomy/adverse effects , Thrombotic Microangiopathies/etiology , Thrombotic Microangiopathies/diagnosis , Acute Kidney Injury/etiology , Acute Kidney Injury/pathology , Image-Guided Biopsy/adverse effects , Immunosuppressive Agents/adverse effects , Biopsy/adverse effects
16.
Clin Radiol ; 79(4): 263-271, 2024 Apr.
Article En | MEDLINE | ID: mdl-38220515

AIM: To investigate the diagnostic performance of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) for thymic epithelial tumours (TETs) and the complication rate after PTNB including seeding after PTNB. MATERIALS AND METHODS: This retrospective study identified PTNBs for anterior mediastinal lesions between May 2007 and September 2021. The diagnostic performance for TETs and complications were investigated. The concordance of the histological grades of TETs between PTNB and surgery was evaluated. The factors associated with pleural seeding after PTNB were determined using Cox regression analysis. RESULTS: Of 387 PTNBs, 235 PTNBs from 225 patients diagnosed as TETs (124 thymomas and 101 thymic carcinomas) and 150 PTNBs from 133 patients diagnosed as other than TETs were included. The sensitivity, specificity, and accuracy for TETs were 89.4% (210/235), 100% (210/210), and 93.5% (360/385), respectively, with an immediate complication rate of 4.4% (17/385). The concordance rate of the histological grades between PTNB and surgery was 73.3% (77/105) after excluding uncategorised types of thymomas. During follow-up after PTNB (median duration, 38.8 months; range, 0.3-164.6 months), no tract seeding was observed. Pleural seeding was observed in 26 patients. Thymic carcinoma (hazard ratio [HR], 5.94; 95% confidence interval [CI], 2.07-17.08; p=0.001) and incomplete resection (HR, 3.29; 95% CI, 1.20-9.02; p=0.02) were associated with pleural seeding, while the biopsy approach type (transpleural versus parasternal) was not associated (p=0.12). CONCLUSIONS: Pretreatment biopsy for TETs was accurate and safe and may be considered for diagnosing TETs, particularly when the diagnosis is challenging and histological diagnosis is mandatory.


Neoplasms, Glandular and Epithelial , Thymoma , Thymus Neoplasms , Humans , Thymoma/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed/methods , Biopsy, Needle/methods , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Thymus Neoplasms/diagnostic imaging , Neoplasms, Glandular and Epithelial/diagnostic imaging
17.
Cardiovasc Intervent Radiol ; 47(5): 604-612, 2024 May.
Article En | MEDLINE | ID: mdl-38263525

PURPOSE: To determine whether instillation of normal saline solution for sealing the needle track reduces incidence of pneumothorax and chest tube placement after computed tomography-guided percutaneous lung biopsy. MATERIALS AND METHODS: A total of 242 computed tomography-guided percutaneous lung biopsies performed at a single institution were retrospectively reviewed, including 93 biopsies in which the needle track was sealed by instillation of 3-5 ml of normal saline solution during needle withdrawal (water seal group) and 149 biopsies without sealing (control group). Patient and lesion characteristics, procedure-specific variables, pneumothorax and chest tube placement rates were recorded. RESULTS: Baseline characteristics were comparable in both groups. There was a statistically significant decrease in the pneumothorax rate (19.4% [18/93] vs. 40.9% [61/149]; p < 0.001) and a numerically lower chest tube placement rate without significant reduction (4.3% [4/93] vs. 10.7% [16/149]; p = 0.126) with using normal saline instillation for sealing the needle track versus not using sealant material. Using a multiple logistic regression analysis, using normal saline instillation to seal the needle track, having a senior radiologist as operator of the procedure and putting patients in prone position were significantly associated with a decreased risk of pneumothorax. The presence of emphysema along the needle track was significantly associated with an increased risk of pneumothorax. No complication was observed due to normal saline injection. CONCLUSION: Normal saline solution instillation for sealing the needle track after computed tomography-guided percutaneous lung biopsy is a simple, low-cost and safe technique resulted in significantly decreased pneumothorax occurrence and a numerically lower chest tube placement rate, and might help to reduce both hospitalization risks and costs for the healthcare system. Level of evidence 3 Non-controlled retrospective cohort study.


Image-Guided Biopsy , Lung , Pneumothorax , Radiography, Interventional , Saline Solution , Tomography, X-Ray Computed , Humans , Pneumothorax/etiology , Pneumothorax/prevention & control , Pneumothorax/epidemiology , Female , Male , Retrospective Studies , Tomography, X-Ray Computed/methods , Middle Aged , Saline Solution/administration & dosage , Incidence , Aged , Image-Guided Biopsy/methods , Image-Guided Biopsy/adverse effects , Lung/diagnostic imaging , Lung/pathology , Radiography, Interventional/methods , Biopsy, Needle/adverse effects , Biopsy, Needle/methods , Chest Tubes , Adult
18.
BMC Pulm Med ; 24(1): 33, 2024 Jan 13.
Article En | MEDLINE | ID: mdl-38218792

OBJECTIVE: This study aimed to assess the incidence and clinical significance of pneumothorax (PTX) and pulmonary hemorrhage (PH) after percutaneous transthoracic lung biopsy (PTLB) guided by C-arm cone-beam computed tomography (CBCT). Furthermore, this study aimed to examine the relationships between PTX and PH with demographics, clinical characteristics, imaging, and PTLB parameters. METHODS: A retrospective analysis was conducted on 192 patients who underwent PTLB at our hospital between January 2019 and October 2022. Incidences of PTX and PH were recorded. PTX was considered clinically significant if treated with chest tube insertion (CTI), and PH if treated with bronchoscopes or endovascular treatments. The various factors on PTX and PH were analyzed using the Chi-squared test and Student t-test. Logistic regression analyses were then used to determine these factors on the correlation to develop PTX and PH. RESULTS: PTX occurred in 67/192 cases (34.9%); CTI was required in 5/67 (7.5%). PH occurred in 63/192 cases (32.8%) and none of these cases required bronchoscopes or endovascular treatments. Lesion diameter (ORPTX = 0.822; ORPH = 0.785), presence of pulmonary emphysema (ORPH = 2.148), the number of samples (ORPH = 1.834), the use of gelfoam (ORPTX = 0.474; ORPH = 0.341) and ablation (ORPTX = 2.351; ORPH = 3.443) showed statistically significant correlation to PTX and PH. CONCLUSIONS: CBCT-guided PTLB is a safe and effective method for performing lung biopsies. The use of gelfoam has been shown to reduce the occurrence of PTX and PH. However, caution should be exercised when combining radiofrequency ablation with PTLB, as it may increase the risk of PTX and PH.


Lung Diseases , Pneumothorax , Humans , Pneumothorax/epidemiology , Pneumothorax/etiology , Pneumothorax/pathology , Incidence , Retrospective Studies , Clinical Relevance , Lung/diagnostic imaging , Lung/pathology , Lung Diseases/diagnostic imaging , Lung Diseases/epidemiology , Lung Diseases/complications , Cone-Beam Computed Tomography , Hemorrhage/epidemiology , Hemorrhage/etiology , Biopsy, Needle/adverse effects , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Risk Factors
19.
Korean J Radiol ; 25(2): 157-165, 2024 Feb.
Article En | MEDLINE | ID: mdl-38288896

OBJECTIVE: We aimed to evaluate the clinical and imaging factors associated with hemorrhagic complications and patient discomfort following ultrasound (US)-guided breast biopsy. MATERIALS AND METHODS: We prospectively enrolled 94 patients who were referred to our hospital between June 2022 and December 2022 for US-guided breast biopsy. After obtaining informed consent, two breast radiologists independently performed US-guided breast biopsy and evaluated the imaging findings. A hemorrhagic complication was defined as the presence of bleeding or hematoma on US. The patients rated symptoms of pain, febrile sensation, swelling at the biopsy site, and dyspnea immediately, 20 minutes, and 2 weeks after the procedure on a visual analog scale, with 0 for none and 10 for the most severe symptoms. Additional details recorded included those of nausea, vomiting, bleeding, bruising, and overall satisfaction score. We compared the clinical symptoms, imaging characteristics, and procedural features between patients with and those without hemorrhagic complications. RESULTS: Of 94 patients, 7 (7%) developed hemorrhagic complications, while 87 (93%) did not. The complication resolved with 20 minutes of manual compression, and no further intervention was required. Vascularity on Doppler examination (P = 0.008), needle type (P = 0.043), and lesion location (P < 0.001) were significantly different between the groups. Patients with hemorrhagic complications reported more frequent nausea or vomiting than those without hemorrhagic complications (29% [2/7] vs. 2% [2/87], respectively; P = 0.027). The overall satisfaction scores did not differ between the two groups (P = 0.396). After 2 weeks, all symptoms subsided, except bruising (50% 2/4 in the complication group and 25% [16/65] in the no-complication group). CONCLUSION: US-guided breast biopsy is a safe procedure with a low complication rate. Radiologists should be aware of hemorrhagic complications, patient discomfort, and overall satisfaction related to this procedure.


Image-Guided Biopsy , Ultrasonography, Interventional , Humans , Prospective Studies , Biopsy, Needle/methods , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Ultrasonography, Interventional/methods , Patient-Centered Care , Nausea/etiology , Vomiting/etiology
20.
Radiology ; 310(1): e230453, 2024 Jan.
Article En | MEDLINE | ID: mdl-38259204

Background Splenic biopsy is rarely performed because of the perceived risk of hemorrhagic complications. Purpose To evaluate the safety of large bore (≥18 gauge) image-guided splenic biopsy. Materials and Methods This retrospective study included consecutive adult patients who underwent US- or CT-guided splenic biopsy between March 2001 and March 2022 at eight academic institutions in the United States. Biopsies were performed with needles that were 18 gauge or larger, with a comparison group of biopsies with needles smaller than 18 gauge. The primary outcome was significant bleeding after the procedure, defined by the presence of bleeding at CT performed within 30 days or angiography and/or surgery performed to manage the bleeding. Categorical variables were compared using the χ2 test and medians were compared using the Mann-Whitney test. Results A total of 239 patients (median age, 63 years; IQR, 50-71 years; 116 of 239 [48.5%] female patients) underwent splenic biopsy with an 18-gauge or smaller needle and 139 patients (median age, 58 years [IQR, 49-69 years]; 66 of 139 [47.5%] female patients) underwent biopsy with a needle larger than 18 gauge. Bleeding was detected in 20 of 239 (8.4%) patients in the 18-gauge or smaller group and 11 of 139 (7.9%) in the larger than 18-gauge group. Bleeding was treated in five of 239 (2.1%) patients in the 18-gauge or smaller group and one of 139 (1%) in the larger than 18-gauge group. No deaths related to the biopsy procedure were recorded during the study period. Patients with bleeding after biopsy had smaller lesions compared with patients without bleeding (median, 2.1 cm [IQR, 1.6-5.4 cm] vs 3.5 cm [IQR, 2-6.8 cm], respectively; P = .03). Patients with a history of lymphoma or leukemia showed a lower incidence of bleeding than patients without this history (three of 90 [3%] vs 28 of 288 [9.7%], respectively; P = .05). Conclusion Bleeding after splenic biopsy with a needle 18 gauge or larger was similar to biopsy with a needle smaller than 18 gauge and seen in 8% of procedures overall, with 2% overall requiring treatment. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Grant in this issue.


Image-Guided Biopsy , Needles , Spleen , Female , Humans , Male , Middle Aged , Angiography , Image-Guided Biopsy/adverse effects , Needles/adverse effects , Needles/statistics & numerical data , Retrospective Studies , Spleen/diagnostic imaging , Spleen/pathology , Aged
...